Wilo-FLA Compact-2 Helix V

Explanation of the name

Example: Wilo-FLA Compact – 2 Helix V 1604 DS8
FLA Fire extinguishing installations
Compact with receiving tank
2 Number of pumps
Helix V Pump Series
16 Nominal flow [m 3 / h]
04 Number of pump sections
DS8 Pressure regulation range: up to 8   bar (depending on pump type)

Overview

Compact system with 2 high-pressure stainless steel centrifugal pumps of the Helix FIRST V series according to DIN 1988 and DIN 14462 (redundancy in a 2-pump system)
Complete system with a cylindrical tank which is approved for potable water applications and connects directly to the pump inlet
Hydraulic capacity: up to 18 m³/h at a delivery height of 100 m
Easy to set up and safe to operate due to FLA control unit (TÜV tested)
Pre-adjusted bypass flow for low flow protection

Type

Pressure booster set for fire water according to DIN 14462, for indirect connection.

With 2 vertical multi-stage stainless steel high-pressure multistage centrifugal pumps with dry rotor and sump.

Application

Automated water supply system for fire-fighting installations with wall-mounted hydrants type "F" in residential, office and public buildings, hotels, hospitals, shopping centers and industrial systems

Equipment/function

  • 2 Helix FIRST V 16, 22 pumps equipped with standard IE2 motors.
  • Automatic pump control with FLA control unit
  • Corrosion resistant parts in contact with the pumped liquid
  • Galvanized steel base frame with height adjustable anti-vibration mounts providing structure-borne sound insulation
  • Stainless steel piping system 1.4301
  • Pressure side shutoff ball valve on each pump
  • Shutoff valve between each pump and accumulation tank
  • Check valve on the pressure side of each pump
  • Pre-adjusted valve at the outlet of each pump to minimize bypass flow
  • Pressure switch on pressure side of each pump
  • Pressure gauge on pressure side
  • Diaphragm pressure tank 8 l, PN 16, located on the pressure side
  • Self venting sump according to DIN 14462, with free outlet according to EN 13077, type AB according to DIN EN 1717
  • Density polyethylene corner tank with water level indicator
  • Drain
    • Float switch as signal transmitter for protection against lack of water
    • Water supply and ventilation via sieve
    • Inspection port with a lid that can be closed hermetically without tools
    • Internal restriction baffles to reduce medium flow rate
    • 2 water inlets, 2 water intake connections
    • Overflow as a free overflow, type AB to DIN EN 1717, no round cross-section

Scope of delivery

  • Pressure boosting system factory assembled, tested for fail-safe operation and leaks, ready for connection
  • Pressure reservoir, ready for connection
  • Packaging
  • Installation and operating instructions

Model overview

Products


Product designation Unit capacity without backup pump Q Gross weight approx. m Maximum working pressure PN Number of pumps Number of standby pumps Article number
FLA Compact-2 Helix V 1604 DS8 18.0 м³/h 389.0 kg 10 bar 2 1 2540130
FLA Compact-2 Helix V 1605 DS8 18.0 м³/h 393.0 kg 10 bar 2 1 2540131
FLA Compact-2 Helix V 1606 DS8 18.0 м³/h 395.0 kg 10 bar 2 1 2540132
FLA Compact-2 Helix V 1607 DS10 18.0 м³/h 406.0 kg 10 bar 2 1 2540133
FLA Compact-2 Helix V 1608 DS16 18.0 м³/h 410.0 kg 16 bar 2 1 2540134
FLA Compact-2 Helix V 1609 DS16 18.0 м³/h 460.0 kg 16 bar 2 1 2540135
FLA Compact-2 Helix V 1610 DS16 18.0 м³/h 464.0 kg 16 bar 2 1 2540136
FLA Compact-2 Helix V 1611 DS16 18.0 м³/h 466.0 kg 16 bar 2 1 2540137
FLA Compact-2 Helix V 2204 DS8 18.0 м³/h 453.0 kg 8 bar 2 1 2540139
FLA Compact-2 Helix V 2205 DS10 18.0 м³/h 473.0 kg 10 bar 2 1 2540140
FLA Compact-2 Helix V 2206 DS16 18.0 м³/h 475.0 kg 16 bar 2 1 2540141
FLA Compact-2 Helix V 2207 DS16 18.0 м³/h 509.0 kg 16 bar 2 1 2540142
FLA Compact-2 Helix V 2208 DS16 18.0 м³/h 579.0 kg 16 bar 2 1 2540143

Those. information

Technical Specifications

  • Mains connection 3~400 V, 50 Hz
  • Max. temperature of pumped liquid: 50 °C
  • Nominal pressure: 16 bar
  • Working pressure: up to 16 bar
  • Inlet pressure from storage tank < 1 bar
  • Nominal internal diameter for pressure connections on the discharge side R 21/2" to R 3"
  • Nominal internal diameter for connection to float valve in the receiving tank: 2 x G2"
  • Control unit protection class IP 54
  • Rectangular sump (540 l)

Materials

  • Impellers, diffusers, stepped casing made of stainless steel 1.4307
  • Pump casing made of cataphoresis coated grey cast iron EN-GJL-250
  • Stainless steel shaft 1.4057
  • 1.4404 Shaft guard
  • EPDM sealing ring (FKM seal on request)
  • Rectangular, high density polyethylene tank, black
  • Stainless steel piping system 1.4301

Download

Colors

DOP

Wilo CAD

The Wilo CAD online library contains DWG drawings of Wilo pumping equipment. In this library, the dimensions of the pumping equipment are given as a guideline. Please note that the contents of the Wilo CAD online library are subject to technical changes.


More in this category:

Need a consultation?

We will tell you in detail about our services, types of work and typical projects, calculate the cost and prepare an individual offer!