Wilo-RexaLift FIT L

Name decoding

Example: Wilo-RexaLift L1-22/T-540-S3/ACx
RexaLift RexaLift sewage lifting unit
FIT Series
L Size
1 Number of pumps installed
22 Maximum head [m]
T Maintenance: M = 1~T = 3~
5 Frequency (5 = 50Hz, 6 = 60Hz)
40 Voltage designation
S3 Setup operating mode: S3=repeat-short-time mode S1=repeat-short-time and continuous mode
A Control unit version: A=standard control unit B=Comfort< control unit;
C Setup operating mode: B = without non-return valve C = with non-return valve
x Other versions:without = free Y = to order

Overview

Low system weight for easy installation
Built-in non-return valve
Flexibility due to free choice of connection point of the supply line
Operational reliability due to integrated thermal motor protection and network-independent alarms for generalized fault signal (SSM) and tank overflow

Type

Sewage lifting unit as a single or dual pump system

Application

Pumping wastewater with faecal matter (in accordance with DIN EN 12050-1) that cannot be piped to the sewer system through the use of natural inclines, and disposal of fluids with backflow protection from discharge points below the backflow level (in accordance with DIN EN 12056-1).

Equipment/function

  • Fully flooded sewage lifting unit (ready for connection), incl. control unit and the following components:
  • Motor winding temperature control sensor
  • Voltage free contact for generalized fault indication (SSM) and tank overflow alarm
  • Nonvolatile alarm
  • Level control by means of a float switch
  • Detachable pump cable
  • Non return valve
  • Sealing for the inflow line
  • Circular saw for the air inlet
  • Hose connection for venting
  • Hose connection for hand membrane pump
  • Pressure pipe connection kit
  • Fixing material
  • Insulating material

Scope of delivery

  • Connection-ready wastewater lifting unit, including:
  • Control unit with non-volatile alarm system and plug
  • 1 seal for supply line DN 100
  • 1 grommet for connection to supply pipe DN 100
  • 1 sleeve for connection of a hand membrane pump or for connection to a supply line Ø 50 mm
  • 1 sleeve for connection to vent DN 70
  • 1 flange adaptor DN 80/100 with flat gasket, gland and fixing material for connection to pressure connection DN 100
  • Storage battery 9 V
  • Noise reducing strips for silent installation
  • Fixing material
  • Installation and operating instructions

Model overview

Those. information

Technical Specifications

  • Mains power connection: 3~400 V, 50 Hz
  • Power consumption P 1: 2.3 ... 3.9 kW
  • Cable length from system to control unit/plug: 4/1.5 m
  • Operating mode: S3-10% 120 s
  • Pumped liquid temperature: 3 to 40 °C, short term: 60 °C max. for 3 minutes
  • ambient temperature: 3 °C ... 40 °C
  • Tank capacity (gross):
    • Single pump unit: 115 l
    • Two-pump system: 140 l
  • Switch-on volume:
    • Single pump unit: 35 l
    • Two-pump system: 50 l
  • Pressure connection: DN 80
  • Connection to supply line: DN 50/DN 100/DN 150
  • Ventilation connection: DN 70
  • Free passage for spherical particles: 40 mm
  • Min. height of inlet connection (installation height to middle of inlet): 180 mm
  • Drainage system protection class: IP67
  • Protection class of control unit: IP54

Materials

  • Motor housing: stainless steel 1.4301 (AISI 304)
  • Fluid body: PE/PUR synthetic material
  • Impeller: synthetic material polyurethane
  • Tank: synthetic material polyethylene

Description/construction

Ready-to-connect and fully floodable sewage lifting unit (flood level: 2 m water column, immersion time: 7 days) with gas- and watertight accumulation tank and backflow preventer.

RexaLift FIT L1:

Single-pump unit with three-phase electric motor, control unit for automatic operation, with CEE plug, potential-free contact for generalized fault alarm, built-in non-volatile alarm and configurable shutdown delay time.

RexaLift FIT L2:

Two-pump unit with three-phase electric motor, control unit for automatic operation (with automatic changeover from standby to peak mode), with CEE plug, potential-free contact for generalized fault alarm, built-in non-volatile alarm and configurable shutdown delay time. Due to the built-in double check valve, only one pressure line needs to be connected.

Warning: The control unit must not be allowed to flood and must therefore be installed in a watertight place.

Download

Colors

DOP

Wilo CAD

The Wilo CAD online library contains DWG drawings of Wilo pumping equipment. In this library, the dimensions of the pumping equipment are given as a guideline. Please note that the contents of the Wilo CAD online library are subject to technical changes.


More in this category:

Need a consultation?