Overview
- Energy savings due to increased system efficiency with Q-Limit function (flow limitation)
- Improved energy efficiency index EEI ≤0.20 for all single pumps
- Optimised display for improved readability and control
- Space-saving installation due to compact design and position-independent LCD display
- Modular concept for connection to all common bus systems (e.g. Modbus, BACnet, CAN, LON, PLR)
- Proven quality and reliability
- Withdrawal program
- After 19 years of success, the Wilo-Stratos high-efficiency pump will be completely removed from the product range by the end of March 2020 and replaced by the new Wilo-Stratos MAXO smart pump. The new Wilo-Stratos MAXO pump technology will continue the success of the Stratos series.
Type
Glandless circulation pump with threaded connection or flange connection, EC motor with automatic speed control.
Application
- All hot water heating systems, air-conditioning systems, closed cooling circuits, industrial circulation systems.
- Equipment/function
Modes of operation
- Manual operation (n = constant)
- Δp-c for constant differential pressure
- Δp-v for variable differential pressure
- Δp-T for differential pressure dependent on temperature control (programmable via IR-Stick, IR-Monitor, Modbus, BACnet, LON or CAN)
- Q-Limit to limit max. flow (can only be set on the IR-Stick)
Manual control
- Setting of operating modes
- Setting the flow rate value
- Setting for automatic speed reduction mode
- Pump ON/OFF setting
- Speed setting (manual switch-over)
Automatic control
- Infinitely variable speed control according to mode of operation
- Automatic downmilling operation
- Lockout function
- Soft start
- Full motor protection with integrated electronic shutdown
External control
- Priority off control input (possible with Stratos IF-modules)
- Minimum power priority input (available with Stratos IF-modules)
- Control input "Analog In 0 - 10V" (remote speed switching), possible with Stratos IF-modules
- Control input "Analog In 0 - 10 V" (remote setpoint adjustment), possible with Stratos IF-modules
Alarms and display
- Generalized fault indication (potential free NO contact)
- Separate fault indication (potential free normally open contact), possible with Stratos IF-Modules
- Lighted fault indicator
- LCD display for the indication of pump parameters and error codes
Data exchange
- Infra-red interface for wireless data exchange with IR-Stick/IR monitor
- Modbus RTU serial digital interface for connection to a building automation system via RS485 bus system (possible with Stratos IF-modules)
- BACnet MS/TP Slave serial digital interface for connection to a building automation system via RS485 bus system (possible with Stratos IF-modules).
- CAN serial digital interface for connection to a building automation system via a bus system (possible with Stratos IF-modules).
- LON serial digital interface to connect to a LONWorks network (available with Stratos IF-Modules)
- PLR serial digital interface for connection to a building automation system via a Wilo interface converter or special communication modules (available with Stratos IF-Modules)
Twin pump control (twin pump or two single pumps)
- Main/standby operation (automatic switchover in the event of malfunction/pump timer operation): various combinations with Stratos IF-Modules (accessories) possible
- Dual pump operation (switch-on second pump during peak demand with efficiency optimisation): various combinations with Stratos IF-Modules (accessories) possible
Accessories
- Keyed casting on pump casing (for pumps with threaded pipe connection P2< 100 W)
- For pumps with flange connection: flange version
- Standard version for pumps DN 32 to DN 65: Combination flange PN 6/10 (flange PN 16 as per EN 1092-2) for counter flanges PN 6 and PN 16
- Standard version for pumps DN 80/DN 100: Flange PN 6 (designed PN 16 as per EN 1092-2) for counter flange PN 6
- Special version for pumps DN 32 to DN 100: Flange PN 16 (acc. to EN 1092-2) for counter flange PN 16
- Socket for the optional addition of Wilo IF-Modules
- Thermal insulation for pumps used in heating systems as standard