MTH-I-ST flowmeter for upflow and continuous temperatures up to 120 °C

MTH-I-ST / MTH-I-F multi-jet flowmeters
Flow meters for flow rates from 1.5 m³/h to 10 m³/h.
Type MTH-I-ST – for vertical installation in ascending pipelines, type MTH-I-F – downstream pipelines.
Meters for vertical installation have connecting and mounting dimensions according to DIN 19648 part 3.

  • For flow rates from 3.5 to 10 m³ / h
  • Consistently high accuracy throughout the entire service life
  • Wide operating range of flow rates
  • Metrological class of accuracy 2
  • Safe operation up to 130 ° C
  • Compatible with multidata WR3 calculators and multipulse WR3 pulse counters

Overview

The specialized flowmeter ZENNER MTH-I-F for vertical pipelines with an upward flow in the flow range from 3.5 to 10 m³ / h. The connecting and construction dimensions are in accordance with DIN 19648-3.


Model overview

Those. information

Principle of operation Multi-jet water meters
Face-to-face length without fittings 135 mm
150 mm
200 mm
Body material brass
Counting mechanism dry ship
Nominal flow qp (Heat meters) qp = 3,5
qp = 6
qp = 10
Nominal diameter DN (mm) DN 20
DN 25
DN 32
DN 40
Nominal size DN (Inch) 3/4 "
1"
1 1/4"
1 1/2"
Water temperature hot water before 120° C
Counter readings in cubic meters (м³)
Metrological class at horizon. position (мах.) A

Download

Colors

DOP

More in this category:

Need a consultation?