Wilo-VeroLine-IP-E

Name decoding

Example IP-E 40/160-4/2-R1
IP-E Pump Inline with electronic control
40 Nominal inner diameter of pipe connection D
160 Nominal inner diameter of the impeller
4 Nominal motor power P2 in kW
2 Number of motor poles
R1 No pressure sensor

Overview

  • Energy savings due to integrated electronic power control system
  • Optional interfaces for bus communication via plug-in IF modules
  • Easy to operate thanks to green button technology and display
  • Integrated dual pump control system
  • Integrated full motor protection (temperature sensor) with electronic switch-off

Type

Electronically regulated, flange-mounted, dry-running, in-line design with automatic power adjustment

Application

Pumping heating water (according to VDI 2035), cold water and water/glycol mixtures without abrasives in heating, air-conditioning and refrigeration applications

Equipment/function

Modes of operation

  • Δp-c for constant differential pressure
  • Δp-v for variable differential pressure
  • PID controller
  • Manual mode (n=continuous)
  • Manual control panel

Green button and display

Manual control

  • Adjustment of flow value
  • Adjustment of speed (manual switch-over)
  • Setting of operating modes
  • Pump ON/OFF setting
  • Configuration of all operating parameters
  • Acknowledgement of errors

External control

  • "Priority off" control input
  • External pump change" control input (only valid for twin pump operation)
  • Analog input 0 - 10 V, 0 - 20 mA for manual control mode (DDC) and remote set point change
  • Analog input 2 - 10 V, 4 - 20 mA for DDC manual operation and remote set point adjustment
  • Analog input 0 - 10 V for pressure transmitter actual value signal
  • Analog input 2-10 V, 0-20 mA, 4-20 mA for pressure transmitter actual value signal

Alarms and Display

  • Generalized fault indication SSM
  • SBM generalized operating state alarm

Data exchange

  • Infrared interface for wireless data exchange with IR-Monitor/IR-Module
  • Socket for Wilo IF-Modules (Modbus, BACnet, CAN, PLR, LON) for connection to Building Management Systems

Protection functions

  • Full motor protection with integrated electronic shut-off
  • Access blocking

Twin pump control (twin pump or two single pumps)

  • Main/Standby operation mode (automatic switchover in case of fault)
  • Main/standby operation, changeover between pumps after 24 hours
  • Parallel operation of two pumps
  • Parallel operation of two pumps (activation of second pump in peak load with efficiency optimisation)

Model overview

Products


Product designation Motor efficiency class Mains connection Version Motor rated powerP2 Pipeline connection Mounting length l0 Gross weight approx. m Article number
VeroLine-IP-E 32/95-0,55/2 IE4 3~380 V, 50/60 Hz with differential pressure sensor 0.55 kW DN 32 260 mm 30.1 kg 2158810
VeroLine-IP-E 32/105-0,75/2 IE4 3~380 V, 50/60 Hz with differential pressure sensor 0.75 kW DN 32 260 mm 33.0 kg 2158811
VeroLine-IP-E 32/125-1,1/2 IE4 3~380 V, 50/60 Hz with differential pressure sensor 1.10 kW DN 32 260 mm 34.6 kg 2158812
VeroLine-IP-E 32/135-1,1/2 IE4 3~380 V, 50/60 Hz with differential pressure sensor 1.10 kW DN 32 260 mm 34.6 kg 2158813
VeroLine-IP-E 32/135-1,5/2 IE4 3~380 V, 50/60 Hz with differential pressure sensor 1.50 kW DN 32 260 mm 41.7 kg 2158814
VeroLine-IP-E 40/115-0,55/2 IE4 3~380 V, 50/60 Hz with differential pressure sensor 0.55 kW DN 40 250 mm 30.1 kg 2158815
VeroLine-IP-E 40/120-1,5/2 IE4 3~380 V, 50/60 Hz with differential pressure sensor 1.50 kW DN 40 320 mm 45.2 kg 2158816
VeroLine-IP-E 40/130-2,2/2 IE4 3~380 V, 50/60 Hz with differential pressure sensor 2.20 kW DN 40 320 mm 45.8 kg 2158817
VeroLine-IP-E 40/150-3/2 IE4 3~380 V, 50/60 Hz with differential pressure sensor 3.00 kW DN 40 320 mm 53.5 kg 2158818
VeroLine-IP-E 40/160-4/2 IE4 3~380 V, 50/60 Hz with differential pressure sensor 4.00 kW DN 40 320 mm 61.3 kg 2158819
VeroLine-IP-E 50/105-0,75/2 IE4 3~380 V, 50/60 Hz with differential pressure sensor 0.75 kW DN 50 280 mm 38.7 kg 2158820
VeroLine-IP-E 50/130-2,2/2 IE4 3~380 V, 50/60 Hz with differential pressure sensor 2.20 kW DN 50 340 mm 48.8 kg 2158821
VeroLine-IP-E 50/140-3/2 IE4 3~380 V, 50/60 Hz with differential pressure sensor 3.00 kW DN 50 340 mm 56.5 kg 2158822
VeroLine-IP-E 50/150-4/2 IE4 3~380 V, 50/60 Hz with differential pressure sensor 4.00 kW DN 50 340 mm 64.3 kg 2158823
VeroLine-IP-E 65/115-1,5/2 IE4 3~380 V, 50/60 Hz with differential pressure sensor 1.50 kW DN 65 340 mm 49.4 kg 2158824
VeroLine-IP-E 65/110-2,2/2 IE4 3~380 V, 50/60 Hz with differential pressure sensor 2.20 kW DN 65 340 mm 50.0 kg 2158825
VeroLine-IP-E 65/120-3/2 IE4 3~380 V, 50/60 Hz with differential pressure sensor 3.00 kW DN 65 340 mm 58.7 kg 2158826
VeroLine-IP-E 65/130-4/2 IE4 3~380 V, 50/60 Hz with differential pressure sensor 4.00 kW DN 65 340 mm 66.5 kg 2158827
VeroLine-IP-E 80/115-2,2/2 IE4 3~380 V, 50/60 Hz with differential pressure sensor 2.20 kW DN 80 360 mm 55.6 kg 2158828
VeroLine-IP-E 80/105-3/2 IE4 3~380 V, 50/60 Hz with differential pressure sensor 3.00 kW DN 80 360 mm 62.8 kg 2158829
VeroLine-IP-E 80/110-4/2 IE4 3~380 V, 50/60 Hz with differential pressure sensor 4.00 kW DN 80 360 mm 70.6 kg 2158830
VeroLine-IP-E 32/95-0,55/2-R1 IE4 3~380 V, 50/60 Hz without differential pressure sensor 0.55 kW DN 32 260 mm 27.6 kg 2158873
VeroLine-IP-E 32/105-0,75/2-R1 IE4 3~380 V, 50/60 Hz without differential pressure sensor 0.75 kW DN 32 260 mm 29.4 kg 2158874
VeroLine-IP-E 32/125-1,1/2-R1 IE4 3~380 V, 50/60 Hz without differential pressure sensor 1.10 kW DN 32 260 mm 31.8 kg 2158875
VeroLine-IP-E 32/135-1,1/2-R1 IE4 3~380 V, 50/60 Hz without differential pressure sensor 1.10 kW DN 32 260 mm 31.8 kg 2158876
VeroLine-IP-E 32/135-1,5/2-R1 IE4 3~380 V, 50/60 Hz without differential pressure sensor 1.50 kW DN 32 260 mm 33.8 kg 2158877
VeroLine-IP-E 40/115-0,55/2-R1 IE4 3~380 V, 50/60 Hz without differential pressure sensor 0.55 kW DN 40 250 mm 27.6 kg 2158878
VeroLine-IP-E 40/120-1,5/2-R1 IE4 3~380 V, 50/60 Hz without differential pressure sensor 1.50 kW DN 40 320 mm 36.8 kg 2158879
VeroLine-IP-E 40/130-2,2/2-R1 IE4 3~380 V, 50/60 Hz without differential pressure sensor 2.20 kW DN 40 320 mm 38.5 kg 2158880
VeroLine-IP-E 40/150-3/2-R1 IE4 3~380 V, 50/60 Hz without differential pressure sensor 3.00 kW DN 40 320 mm 44.8 kg 2158881
VeroLine-IP-E 40/160-4/2-R1 IE4 3~380 V, 50/60 Hz without differential pressure sensor 4.00 kW DN 40 320 mm 52.8 kg 2158882
VeroLine-IP-E 50/105-0,75/2-R1 IE4 3~380 V, 50/60 Hz without differential pressure sensor 0.75 kW DN 50 280 mm 33.2 kg 2158883
VeroLine-IP-E 50/130-2,2/2-R1 IE4 3~380 V, 50/60 Hz without differential pressure sensor 2.20 kW DN 50 340 mm 41.5 kg 2158884
VeroLine-IP-E 50/140-3/2-R1 IE4 3~380 V, 50/60 Hz without differential pressure sensor 3.00 kW DN 50 340 mm 47.5 kg 2158885
VeroLine-IP-E 50/150-4/2-R1 IE4 3~380 V, 50/60 Hz without differential pressure sensor 4.00 kW DN 50 340 mm 55.5 kg 2158886
VeroLine-IP-E 65/115-1,5/2-R1 IE4 3~380 V, 50/60 Hz without differential pressure sensor 1.50 kW DN 65 340 mm 40.5 kg 2158887
VeroLine-IP-E 65/110-2,2/2-R1 IE4 3~380 V, 50/60 Hz without differential pressure sensor 2.20 kW DN 65 340 mm 43.5 kg 2158888
VeroLine-IP-E 65/120-3/2-R1 IE4 3~380 V, 50/60 Hz without differential pressure sensor 3.00 kW DN 65 340 mm 50.0 kg 2158889
VeroLine-IP-E 65/130-4/2-R1 IE4 3~380 V, 50/60 Hz without differential pressure sensor 4.00 kW DN 65 340 mm 58.0 kg 2158890
VeroLine-IP-E 80/115-2,2/2-R1 IE4 3~380 V, 50/60 Hz without differential pressure sensor 2.20 kW DN 80 360 mm 51.7 kg 2158891
VeroLine-IP-E 80/105-3/2-R1 IE4 3~380 V, 50/60 Hz without differential pressure sensor 3.00 kW DN 80 360 mm 55.3 kg 2158892
VeroLine-IP-E 80/110-4/2-R1 IE4 3~380 V, 50/60 Hz without differential pressure sensor 4.00 kW DN 80 360 mm 63.3 kg 2158893

Those. information

Specifications

  • Permissible temperature range -20° C to +120° C
  • Mains connection
    • 3~400 V ± 10 %, 50 Hz
    • 3~380 V -5 % +10 %, 60 Hz
  • Protection class IP 55
  • Nominal internal diameter DN 32 to DN 80
  • Max. operating pressure 10 bar (special version: 16 bar)

Materials

  • Pump casing and connection: EN-GJL-250
  • Impeller: PPO-GF30
  • Shaft: 1.4021
  • Mechanical seal: AQEGG; other mechanical seals on request

Description/construction

Single-stage low-pressure centrifugal pump in Inline design with the following features:

  • Mechanical seal, gliding
  • Flanged connection
  • Drive with integrated electronic speed control system

Download

Colors

DOP

Wilo CAD

The Wilo CAD online library contains DWG drawings of Wilo pumping equipment. In this library, the dimensions of the pumping equipment are given as a guideline. Please note that the contents of the Wilo CAD online library are subject to technical changes.


More in this category:

Need a consultation?

We will tell you in detail about our services, types of work and typical projects, calculate the cost and prepare an individual offer!