AQUAPRESSO

Overview

Expansion tanks with permanent gas filling for drinking water supply systems. Flowfresh technology provides a unique level of hygiene.

Maintaining pressure in water supply systems
Expansion tanks with permanent gas filling for drinking water supply systems. The sealed butyl rubber chamber is suitable for use in potable water systems. Flowfresh technology provides a unique level of hygiene.


Model overview

Aquapresso AD

Disc-shaped. Installation with bottom connection


Aquapresso AD

A type VN[l] D H** m[kg] S EAN № product
10 bar (PS)
AD 8.10 8 314 166 3,8 R1/2 7640148633772 711 1000
AD 12.10 12 352 201 5,1 R1/2 7640148633789 711 1001
AD 18.10 18 393 224 6,5 R3/4 7640148633796 711 1002
AD 25.10 25 436 251 8,2 R3/4 7640148633802 711 1003
AD 35.10 35 485 280 10,1 R3/4 7640148633819 711 1004
AD 50.10 50 536 317 12,6 R1 7640148633826 711 1005
AD 80.10 80 636 347 16,9 R1 7640148633833 711 1006
  • VN = Nominal volume
  • **) deviation 0 /+35.
Aquapresso ADF

Disc-shaped. Top and bottom connection, suitable for flow in any direction. Flowfresh is a flow model.


Aquapresso ADF

A type VN[l] D H** m[kg] S qN[m3/h] EAN № product
10 bar (PS)
ADF 8.10 8 345 166 4 2x R1/2 0,6 7640148633840 711 2000
ADF 12.10 12 386 201 5,3 2x R1/2 0,6 7640148633857 711 2001
ADF 18.10 18 430 224 6,6 2x R3/4 1,0 7640148633864 711 2002
ADF 25.10 25 472 251 8,5 2x R3/4 1,0 7640148633871 711 2003
ADF 35.10 35 521 280 10,4 2x R3/4 1,0 7640148633888 711 2004
ADF 50.10 50 587 317 13 2x R1 1,7 7640148633895 711 2005
ADF 80.10 80 687 347 17,4 2x R1 1,7 7640148633901 711 2006
  • VN = Nominal volume
  • **) deviation 0 / + 35.
Aquapresso AU

Cylindrical model.


Aquapresso AU

A type VN[l] D H H*** m[kg] S EAN № product
10 bar (PS)
AU 140.10 140 420 1274 1523 33 R1 1/4 7640148633918 711 1007
AU 200.10 200 500 1330 1566 41 R1 1/4 7640148633925 711 1008
AU 300.10 300 560 1451 1694 60 R1 1/4 7640148633932 711 1009
AU 400.10 400 620 1499 1761 70 R1 1/4 7640148633949 711 1010
AU 500.10 500 680 1588 1859 90 R1 1/4 7640148633956 711 1011
AU 600.10 600 740 1596 1872 108 R1 1/4 7640148633963 711 1012
  • VN = Nominal volume
  • ***) Max. height when the tank is tilted
Aquapresso AUF

Cylindrical model. Flowfresh - flow model, flow direction only from top to bottom.


Aquapresso AUF

A type VN[l] D H H*** m[kg] S qN[m3/h] EAN № product
10 bar (PS)
AUF 140.10 140 420 1274 1562 34 2x R1 1/4 7,3 7640148633970 711 2007
AUF 200.10 200 500 1330 1577 42 2x R1 1/4 7,3 7640148633987 711 2008
AUF 300.10 300 560 1451 1711 61 2x R1 1/4 7,3 7640148633994 711 2009
AUF 400.10 400 620 1499 1773 71 2x R1 1/4 7,3 7640148634007 711 2010
AUF 500.10 500 680 1588 1870 91 2x R1 1/4 7,3 7640148634014 711 2011
  • VN = Nominal volume
  • ***) Max. height when the tank is tilted
Aquapresso AG

Cylindrical model.


Aquapresso AG

A type VN[l] D H** H*** m[kg] SEN 1092-1 EAN № product
10 bar (PS)
AG 700.10 700 750 1901 1936 250 DN 50 7640148634038 711 1013
AG 1000.10 1000 850 2070 2126 340 DN 65 7640148634045 711 1014
AG 1500.10 1500 1016 2253 2328 460 DN 65 7640148634052 711 1015
AG 2000.10 2000 1016 2773 2826 760 DN 80 7640148634069 711 1020
AG 3000.10 3000 1300 2871 2955 920 DN 80 7640148634076 711 1017
AG 4000.10 4000 1300 3518 3580 1060 DN 80 7640148634083 711 1018
AG 5000.10 5000 1300 4161 4202 1180 DN 80 7640148634090 711 101
16 bar (PS)
AG 300.16 300 500 1824 1839 180 DN 50 7640148634175 711 3000
AG 500.16 500 650 1879 1906 250 DN 50 7640148634182 711 3001
AG 700.16 700 750 1954 1988 290 DN 50 7640148634199 711 3002
AG 1000.16 1000 850 2103 2159 390 DN 65 7640148634205 711 3003
AG 1500.16 1500 1016 2256 2331 520 DN 65 7640148634212 711 3004
AG 2000.16 2000 1016 2792 2845 840 DN 80 7640148634229 711 3009
AG 3000.16 3000 1300 2898 2982 1000 DN 80 7640148634236 711 3006
AG 4000.16 4000 1300 3543 3607 1170 DN 80 7640148634243 711 3007
AG 5000.16 5000 1300 4188 4230 1310 DN 80 7640148634250 711 3008
  • VN = Nominal volume
  • ***) Max. height when the tank is tilted
Aquapresso AGF

Cylindrical model. Flowfresh - flow model, flow direction only from top to bottom.


Aquapresso AGF

A type VN[l] D H** H*** m[kg] SEN 1092-1 qN[m3/h] EAN № product
10 bar (PS)
AGF 700.10 700 750 1970 2062 260 2xDN 50 11,5 7640148634106 711 2013
AGF 1000.10 1000 850 2171 2310 355 2xDN 65 19,5 7640148634113 711 2014
AGF 1500.10 1500 1016 2354 2510 475 2xDN 65 19,5 7640148634120 711 2015
AGF 2000.10 2000 1016 2925 3084 775 2xDN 80 31,0 7640148634137 711 2020
AGF 3000.10 3000 1300 3022 3228 935 2xDN 80 31,0 7640148634144 711 2017
AGF 4000.10 4000 1300 3668 3839 1080 2xDN 80 31,0 7640148634151 711 2018
AGF 5000.10 5000 1300 4313 4459 1200 2xDN 80 31,0 7640148634168 711 2019
16 bar (PS)
AGF 300.16 300 500 1891 1947 200 2xDN 50 11,5 7640148634267 711 4000
AGF 500.16 500 650 1946 2021 270 2xDN 50 11,5 7640148634274 711 4001
AGF 700.16 700 750 1970 2062 300 2xDN 50 11,5 7640148634281 711 4002
AGF 1000.16 1000 850 2218 2354 410 2xDN 65 19,5 7640148634298 711 4003
AGF 1500.16 1500 1016 2371 2526 540 2xDN 65 19,5 7640148634304 711 4004
AGF 2000.16 2000 1016 2941 3099 860 2xDN 80 31,0 7640148634311 711 4009
AGF 3000.16 3000 1300 3046 3252 1040 2xDN 80 31,0 7640148634328 711 4006
AGF 4000.16 4000 1300 3691 3863 1195 2xDN 80 31,0 7640148634335 711 4007
AGF 5000.16 5000 1300 4336 4482 1335 2xDN 80 31,0 7640148634342 711 4008
  • VN = Nominal volume
  • **) deviation 0 / -100.
  • ***) Max. height when the tank is tilted
Pressure gauge for preset pressure DME


Манометр

A type PS[bar] m[kg] EAN № product
DME 10 0,3 7640148638593 500 1048

Those. information

Application area:
Potable water heating systems, pressure boosting systems, maximum chloride content 125 mg / l (70 ° C), 250 mg / l (45 ° C).
Pressure:
Minimum allowable pressure, PSmin: 0 bar
Maximum allowable pressure, PS: see article numbers
Minimum air side pressure (p0), factory setting: 4 bar
Temperature:
Maximum permissible temperature, TS: 120 ° C
Minimum allowable temperature, TSmin: -10 ° C
Maximum allowable chamber temperature, TB: 70 ° C
Minimum permissible chamber temperature, TBmin: 5 ° C
Material:
Steel. Beryllium color.
All metal parts in contact with water are made of stainless steel.
Transport and storage:
In warm and dry places.
Standards:
Manufactured according to PED 2014/68 / EU.

PRESET PRESSURE GAUGE

Application area:
Heating, drinking water supply, heat and cold supply.
Use in systems according to EN 12828, SWKI 93-1.
Function:
Preset pressure control in expansion vessels. Auto ON / OFF. Automatic calibration.
Pressure:
Minimum allowable pressure, PSmin: 0 bar
Maximum allowable pressure, PS: 10 bar
Temperature:
Maximum permissible temperature, TS: 120 ° C
Minimum allowable temperature, TSmin: -10 ° C
Material:
Plastic.