for example: | Wilo-Sub TWU 4-0203-C-QC-GT |
TWU | Submersible pump |
4 | Diameter of hydraulic part in inches ["] |
02 | Nominal flow [m3/h] |
03 | Number of hydraulic stages |
C | Pump generation designation |
I | Motor housing made of steel 1.4571, motor connection via flat plug |
QC | Quick Connect Cable Quick Connect Cable for easy and quick extension of motor cable |
Quick Connect Cable. | |
GT | for geothermal installations |
Type
Multistage submersible motor pump 4" casing version for vertical or horizontal installation
Application
Equipment/function
Scope of delivery
Product designation | Mains connection | Motor diameter DM | Pressure head max. Hmax | Max. Qmax | Nominal motor power P2 | Gross weight approx. m | Article number |
---|---|---|---|---|---|---|---|
Sub TWU 4.02-03-DM-CI-GT | 3~400 V, 50 Hz | 95 mm | 20.0 m | 4.0 m³/h | 0.25 kW | 9.4 kg | 6079004 |
Sub TWU 4.02-03-DM-CI-QC-GT | 3~400 V, 50 Hz | 95 mm | 20.0 m | 4.0 m³/h | 0.25 kW | 9.4 kg | 6079005 |
Sub TWU 4.02-04-DM-CI-GT | 3~400 V, 50 Hz | 95 mm | 26.7 m | 4.0 m³/h | 0.25 kW | 9.6 kg | 6079006 |
Sub TWU 4.02-04-DM-CI-QC-GT | 3~400 V, 50 Hz | 95 mm | 26.7 m | 4.0 m³/h | 0.25 kW | 9.6 kg | 6079007 |
Sub TWU 4.04-04-DM-CI-GT | 3~400 V, 50 Hz | 95 mm | 23.5 m | 6.3 m³/h | 0.25 kW | 9.9 kg | 6079008 |
Sub TWU 4.04-04-DM-CI-QC-GT | 3~400 V, 50 Hz | 95 mm | 23.5 m | 6.3 m³/h | 0.25 kW | 9.9 kg | 6079009 |
Sub TWU 4.04-05-DM-CI-GT | 3~400 V, 50 Hz | 95 mm | 29.4 m | 6.3 m³/h | 0.37 kW | 11.9 kg | 6079010 |
Sub TWU 4.04-05-DM-CI-QC-GT | 3~400 V, 50 Hz | 95 mm | 29.4 m | 6.3 m³/h | 0.37 kW | 11.9 kg | 6079011 |
Technical Specifications
Materials
Description/construction
Hydraulic part
Multistage submersible pump with radial or semi-axial impellers in split casing design. Integral check valve. All parts in contact with pumped liquid are made of corrosion resistant materials.
Electric motor
Corrosion proof three-phase direct start motor. Pressure proof electric motor, encapsulated in resin, windings with insulating coating, self-lubricating bearings, water-glycol mixture.
Cooling
Electric motor is cooled by pumped fluid. The motor must only be operated in immersed state. The maximum temperature limits for the pumped liquid and the minimum flow speed must be observed. Vertical installation can be carried out with or without a cooling jacket - at the customer's choice. Horizontal installation is done with a cooling jacket.
The Wilo CAD online library contains DWG drawings of Wilo pumping equipment. In this library, the dimensions of the pumping equipment are given as a guideline. Please note that the contents of the Wilo CAD online library are subject to technical changes.