PROFIL Т6

Heaters can operate in a wide range of coolant temperatures:

  • Heat medium temperature from 40 to 90 °C
  • Ideal heat output when working with a low-temperature coolant (heat pumps, electric boilers)

Huge savings for new construction and renovation:

  • Up to 15% more heat dissipation compared to other heaters (compatibility with older heating systems)
  • High heat dissipation allows you to reduce the size of the radiator

Quick heating and cooling of appliances

  • Fast response time to sudden temperature changes (less power consumption)
  • High efficiency during short heating and cooling times
  • The ability to precisely maintain the temperature in the room 

Overview

T6: a revolution among radiators

Radiators with a central bottom connection VOGEL&NOOT T6 have set a new standard in space heating! Ease of installation and operation - these are the features of VOGEL&NOOT, from which everyone benefits! The T6 central connection technology is based on symmetry. The T6 central connection node is located clearly in the center of the radiator, regardless of its length. It is the perfect combination of design with unique technology. Center connection radiators also use a patented convection grille geometry that increases the heat output of the radiator. This allows you to quickly heat up the room and guarantees an optimal level of comfort.


Versatility


Connection to the heating system is possible through any of the 6 branch pipes. Connection

Easy resizing


It is easy to change the size of the radiator even after installation is completed.Change the size

Convenient control


The thermostatic element can be installed on either side of the radiator.Easy operation

Optimal Mounts


It is possible to supply radiators without brackets on the rear wall of the radiator.Optimal Mounts

Distance from the wall


Standard wall distance for all types of centrally connected radiators.Wall distance

Convenient installation


It is possible to install a bypass for testing a heating system without a radiator.Easy installation

Model overview

Тип 11VM


Тип 21VM-S


Тип 22 VM


Тип 33 VM


Those. information

Connection in two-pipe system mode


A) Connection on one side
B) Connection from 2 sides
C) Connection from above (Warning: reduced power)

T6 connection modes

Feed  feed

Returnreturn< /p>

Stub stub< /p>

Air vent air vent< /p>

Drain drain

Warning:
When T6 radiators with central bottom connection are used as radiators with side connection ¾ plastic screw plugs must be replaced with nickel-plated brass plugs (optional). Available by part number: AZ0PL000C0002000. Additionally, the plastic parts of the special threaded connections must be removed.

Preset Kv values


Preconfigured Kv values

It is also possible to change the preset kv value of the thermostatic valve when the equipment is used under pressure.

Connection in two-pipe system mode


T6 Recommendations for 2-pipe connection

Setup instructions: 
VOGEL&NOOT valve radiators are made in accordance with the installation in a 2-pipe heating system. Each individual radiator has a pre-installed thermostatic valve, according to the radiator output. The set kv value is also indicated by the color of its cap.  

Please note: 
If it is necessary to adjust the kv value, it can be set arbitrarily on the thermostatic valve. Changing the installation location of the thermostatic valve from the left side to the right side, and vice versa, is possible at any time during operation. Radiators are supplied with protective plugs. After removing the protective plug (position A), the corresponding thermostatic head can be installed directly on the built-in thermostatic valve (position B): “RA 2000”,“RAW” by Danfoss“VK” by Heimeier“D” by Herz“thera DA” by MNG and “UNI XD” by Oventrop.

One-pipe connection


In a one-pipe heating system, the built-in thermostatic valve must be set to N. 

A protective plug is installed on the built-in thermostatic valve. After removing the protective plug, a standard RA thermostatic head can be installed on the thermostatic valve. 

ATTENTION: When installing a radiator in a single-pipe heating system, it is necessary to provide for the installation of a connection unit with a bypass. If there is no bypass at the connection point, the heating system will not work.

Changing the built-in thermostatic valve from the right side to the left side, and vice versa, can be easily done at any time.

Download

Colors

8 sanitary colors


8 trendy RAL colors


25 classic RAL colors


4 metallic colors


DOP

CE Marking and "DECLARATION OF QUALITY FEATURES, Declaration of Performance for Construction Products, Declaration of Performance" (DoP)


According to the EU regulation "On construction products" products used in construction, including radiators and convectors without a built-in heating element, must receive the CE marking on the basis of the harmonized product standards EN442, and have a "DECLARATION OF QUALITY DATA, Declaration of performance of construction products, declaration of performance" (DoP). The CE marking means that each individual product is manufactured in accordance with the requirements of the technological process for this type of product, established by the regulations regarding its production, testing and delivery. The regulation entered into force on July 1, 2013  

RettigICC products carry the CE mark. The RettigICC`s "Declaration of Performance, Declaration of Performance, Declaration of Performance" by RettigICC, as well as documents detailing the performance of individual products (see appendices M and D) are available from in accordance with the provisions of the regulation "On construction products"; (See the attached RICC Statement of Performance in its latest edition and the documents it references.)

More in this category:

Need a consultation?

We will tell you in detail about our services, types of work and typical projects, calculate the cost and prepare an individual offer!